B4100

  • 5 1/2 Digit

  • True RMS

  • Full Autoranging

  • Frequency, Capacitance Measurement

  • Trend Plot Capability

  • Programmable Function Hi - Lo, Relative, Error %, Recording (Max. Min. and True Average)

  • RS232C Interface and GPIB (Optional)

  • DC Voltage

    Range

    Resolution

    Accuracy

    200.0mV ~  1000V

    0.001mV ~ 0.01V

    (0.5%rdg+3d)
    at 23 5

     - Input Impedance : 10M
     - Overload Protection : 1000V
  • AC Voltage

    Range

    Resolution

    Accuracy

    2V ~ 1000V

    0.00001V ~ 0.01V

    (0.5%rdg+3d)
    at 23 5

     - Crest Factor :  3:1
     - Input Impedance : 10M
     - Overload Protection : 1000V
  • DC Current

    Range

    Resolution

    Accuracy

    2mA ~ 10V

    0.00001V ~ 0.01V

    (0.1%rdg+5d)
    at 23 5

     - Input Impedance : 200mV
     - Overload Protection : Fused
  • AC Current

    Range

    Resolution

    Accuracy

    2mA ~ 10A

    0.00001mA ~ 0.0001A

    (0.5%rdg+5d)
    at 23 5

     - Overload Protection : 600V
     
  • Resistance

    Range

    Resolution

    Accuracy

    200 ~ 10M

    0.001 ~ 0.0001

    (0.5%rdg+5d)
    at 23 5

     - Overload Protection : 600V
     
  • General

    Interface :
    RS232C
    - 9Pin Serial Port
    - Full Function and Range Remote Control
    - 1200, 2400,4800,9600 BPS User Selectable
     
    Display 128 by 64 Pixel Super Twisted LCD
    Operating
    Temperature
    0~50 (Accuracy Specified at 25 5)
    Dimension 296mm(W) × 285mm(D) × 83mm(H)
    Power 85V to 270Vac (10%, 48 to 66Hz)
    Standard Accessories Power Cord, BNC Cable, Fuse, Instrument Manual